{"id":53,"date":"2016-07-23T12:00:10","date_gmt":"2016-07-23T10:00:10","guid":{"rendered":"http:\/\/www.safety-services.at\/?page_id=53"},"modified":"2024-03-11T16:43:34","modified_gmt":"2024-03-11T15:43:34","slug":"risikobeurteilung","status":"publish","type":"page","link":"https:\/\/www.safety-services.at\/en\/risikobeurteilung\/","title":{"rendered":"Risk assessment according Machinery Directive 2006\/42\/EC"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-115 aligncenter\" src=\"http:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/08\/Stern_rot_gr_RB_nb.png\" alt=\"Stern_rot_gr_RB_nb\" width=\"107\" height=\"106\" \/><\/p>\n<p>4S carries out a written risk assessment for your machine. A risk assessment is a legal requirement according Machinery Directive 2006\/42\/EC and has to be conducted by every manufacturer of a machine. According Annex I of the directive:<\/p>\n<blockquote><p>The manufacturer of machinery or his authorised representative must ensure that a risk assessment is carried<br \/>\nout in order to determine the health and safety requirements which apply to the machinery. The machinery<br \/>\nmust then be designed and constructed taking into account the results of the risk assessment.<\/p><\/blockquote>\n<p>You might even become a manufacturer of a &#8220;new&#8221; machine when modifying your machinery in a scope which is not the intended use.<br \/>\nWhen building partly completed machinery you also have to carry out a risk assessment.<\/p>\n<p>The\u00a0international standard <em>EN ISO 12100 <\/em><em>Safety of machinery &#8211; General principles for design &#8211; Risk assessment and risk reduction<\/em> will be the basis of the risk assessment carried out by 4S. This standard is harmonized according Machinery Directive 2006\/42\/EC which means simplified: When you fulfill the requirements of the standard you also meet the requirements of the directive.<br \/>\nYou ar insecure if you are a manufacturer of machinery or partly completed machinery and have to carry out a risk assessment?<\/p>\n<p><a href=\"https:\/\/www.safety-services.at\/en\/kontakt\/\">CONTACT 4S<\/a>. 4S supports you to clarify your legal requirements when building or modifying machinery.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>4S carries out a written risk assessment for your machine. A risk assessment is a legal requirement according Machinery Directive 2006\/42\/EC and has to be conducted by every manufacturer of a machine. According Annex I of the directive: The manufacturer of machinery or his authorised representative must ensure that a risk assessment is carried out&hellip;<\/p>\n<p class=\"more-link-wrapper\"><a class=\"more-link\" href=\"https:\/\/www.safety-services.at\/en\/risikobeurteilung\/\">Continue<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-53","page","type-page","status-publish","hentry"],"translation":{"provider":"WPGlobus","version":"3.0.4","language":"en","enabled_languages":["de","en"],"languages":{"de":{"title":true,"content":true,"excerpt":false},"en":{"title":true,"content":true,"excerpt":false}}},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Risk assessment according Machinery Directive 2006\/42\/EC - 4S - Sascha Steinkrau\u00df Safety Services<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.safety-services.at\/risikobeurteilung\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Risk assessment according Machinery Directive 2006\/42\/EC - 4S - Sascha Steinkrau\u00df Safety Services\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.safety-services.at\/risikobeurteilung\/\" \/>\n<meta property=\"og:site_name\" content=\"4S - Sascha Steinkrau\u00df Safety Services\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-11T15:43:34+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/08\/Stern_rot_gr_RB_nb.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/\",\"url\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/\",\"name\":\"Risk assessment according Machinery Directive 2006\\\/42\\\/EC - 4S - Sascha Steinkrau\u00df Safety Services\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.safety-services.at\\\/wp-content\\\/uploads\\\/2016\\\/08\\\/Stern_rot_gr_RB_nb.png\",\"datePublished\":\"2016-07-23T10:00:10+00:00\",\"dateModified\":\"2024-03-11T15:43:34+00:00\",\"description\":\"4S erstellt f\u00fcr Sie eine schriftlich dokumentierte Risikobeurteilung gem\u00e4\u00df Maschinenrichtlinie 2006\\\/42\\\/EG. arbeitssicherheit dienstleistungen\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/#primaryimage\",\"url\":\"http:\\\/\\\/www.safety-services.at\\\/wp-content\\\/uploads\\\/2016\\\/08\\\/Stern_rot_gr_RB_nb.png\",\"contentUrl\":\"http:\\\/\\\/www.safety-services.at\\\/wp-content\\\/uploads\\\/2016\\\/08\\\/Stern_rot_gr_RB_nb.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/risikobeurteilung\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.safety-services.at\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Risikobeurteilung gem\u00e4\u00df Maschinenrichtlinie 2006\\\/42\\\/EG\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/#website\",\"url\":\"https:\\\/\\\/www.safety-services.at\\\/\",\"name\":\"4S - Sascha Steinkrau\u00df Safety Services e.U.\",\"description\":\"...so sind sie sicher!\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.safety-services.at\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/#organization\",\"name\":\"4S - Sascha Steinkrau\u00df Safety Services e.U.\",\"url\":\"https:\\\/\\\/www.safety-services.at\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.safety-services.at\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/cropped-4S_red_s_nb.png\",\"contentUrl\":\"https:\\\/\\\/www.safety-services.at\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/cropped-4S_red_s_nb.png\",\"width\":351,\"height\":102,\"caption\":\"4S - Sascha Steinkrau\u00df Safety Services e.U.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.safety-services.at\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/sascha-steinkrau-6b3248117\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Risk assessment according Machinery Directive 2006\/42\/EC - 4S - Sascha Steinkrau\u00df Safety Services","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.safety-services.at\/risikobeurteilung\/","og_locale":"en_US","og_type":"article","og_title":"Risk assessment according Machinery Directive 2006\/42\/EC - 4S - Sascha Steinkrau\u00df Safety Services","og_url":"https:\/\/www.safety-services.at\/risikobeurteilung\/","og_site_name":"4S - Sascha Steinkrau\u00df Safety Services","article_modified_time":"2024-03-11T15:43:34+00:00","og_image":[{"url":"http:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/08\/Stern_rot_gr_RB_nb.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.safety-services.at\/risikobeurteilung\/","url":"https:\/\/www.safety-services.at\/risikobeurteilung\/","name":"Risk assessment according Machinery Directive 2006\/42\/EC - 4S - Sascha Steinkrau\u00df Safety Services","isPartOf":{"@id":"https:\/\/www.safety-services.at\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.safety-services.at\/risikobeurteilung\/#primaryimage"},"image":{"@id":"https:\/\/www.safety-services.at\/risikobeurteilung\/#primaryimage"},"thumbnailUrl":"http:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/08\/Stern_rot_gr_RB_nb.png","datePublished":"2016-07-23T10:00:10+00:00","dateModified":"2024-03-11T15:43:34+00:00","description":"4S erstellt f\u00fcr Sie eine schriftlich dokumentierte Risikobeurteilung gem\u00e4\u00df Maschinenrichtlinie 2006\/42\/EG. arbeitssicherheit dienstleistungen","breadcrumb":{"@id":"https:\/\/www.safety-services.at\/risikobeurteilung\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.safety-services.at\/risikobeurteilung\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.safety-services.at\/risikobeurteilung\/#primaryimage","url":"http:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/08\/Stern_rot_gr_RB_nb.png","contentUrl":"http:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/08\/Stern_rot_gr_RB_nb.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.safety-services.at\/risikobeurteilung\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.safety-services.at\/"},{"@type":"ListItem","position":2,"name":"Risikobeurteilung gem\u00e4\u00df Maschinenrichtlinie 2006\/42\/EG"}]},{"@type":"WebSite","@id":"https:\/\/www.safety-services.at\/#website","url":"https:\/\/www.safety-services.at\/","name":"4S - Sascha Steinkrau\u00df Safety Services e.U.","description":"...so sind sie sicher!","publisher":{"@id":"https:\/\/www.safety-services.at\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.safety-services.at\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.safety-services.at\/#organization","name":"4S - Sascha Steinkrau\u00df Safety Services e.U.","url":"https:\/\/www.safety-services.at\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.safety-services.at\/#\/schema\/logo\/image\/","url":"https:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/05\/cropped-4S_red_s_nb.png","contentUrl":"https:\/\/www.safety-services.at\/wp-content\/uploads\/2016\/05\/cropped-4S_red_s_nb.png","width":351,"height":102,"caption":"4S - Sascha Steinkrau\u00df Safety Services e.U."},"image":{"@id":"https:\/\/www.safety-services.at\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/in\/sascha-steinkrau-6b3248117\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/pages\/53","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/comments?post=53"}],"version-history":[{"count":22,"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/pages\/53\/revisions"}],"predecessor-version":[{"id":432,"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/pages\/53\/revisions\/432"}],"wp:attachment":[{"href":"https:\/\/www.safety-services.at\/en\/wp-json\/wp\/v2\/media?parent=53"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}